Product Identification

Product ID:R6K9, STRIPPABLE COATING REDUCER (ACETONE)
MSDS Date:12/30/1986
FSC:8010
NIIN:00N033259
MSDS Number: BPNSP

Responsible Party
SHERWIN-WILLIAMS CO
101 PROSPECT AVE NW
CLEVELAND, OH 44115
US

Emergency Phone: 216-566-2917

Info Phone: 216-566-2902

Cage: 54636

Contractor
SHERWIN-WILLIAMS CO THE
CLEVELAND, OH 44115-1042 US

Telephone: 800-251-2486/216-566-2242

Cage: 54636

Ingredients

180.

CAS: 67-64-1

RTECS: AL3150000

Fraction By Weight: 100%

OSHA PEL 1000PPM

ACGIH TLV: 750PPM/1000STEL;9293

EPA Report Quantity: 5000 LBS

DOT Report Quantity: 5000 LBS


WHEN NOT IN USE. TRANSFER ONLY TO APPRVD CNTNRS

RTECS: 9999999ZZ


OUT OF REACH OF CHILDREN.

RTECS: 9999999ZZ


1910.94, 1910.107, 1910.108.

RTECS: 9999999ZZ

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:NO Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE:OVEREXPOSURE CAUSES EYE, SKIN &
RESPIRATORY IRRITATION. MAY CAUSE NERVOUS SYSTEM DEPRESSION
ACCOMPANIED BY HEADACHE, DIZZINESS, NAUSEA, CONFUSION & STAGGERING
GAIT. EXTREME OVEREXPOSURE MAY RESU LT IN UNCONSCIOUSNESS &
POSSIBLY DEATH.CHRONIC:REPORTS HAVE ASSOCIATED REPEATED & PROLONGED
(EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:HLTH HAZ:OVEREXPOSURE TO SOLVENTS W/PERMANENT
BRAIN & NERVOUS SYSTEM DAMAGE. INTENTIONAL MISUSE BY DELIBERATELY
CONCENTRATING & INHALING CONTENTS CAN BE HARMFUL OR FATAL.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.

First Aid

First Aid:INGEST:CALL MD IMMEDIATELY . INHAL:REMOVE FROM EXPOSURE.
RESTORE BREATHING. KEEP WARM & QUIET. SKIN:WASH AFFECTED AREA
THOROUGHLY W/SOAP & WATER. EYES:FLUSH W/LARGE AMOUNTS OF WATER FOR
AT LEAST 15 MINUTES. GET MEDICAL ATTENTION.

Fire Fighting

Flash Point Method:TCC
Flash Point:1F,-17C
Lower Limits:2.2%
Extinguishing Media:CO*2, DRY CHEMICAL, FOAM.
Fire Fighting Procedures:WEAR NIOSH/MSHA APPRVD SCBA & FULL PROT EQUIP
. H*2O SPRAY MAY BE INEFT. IF H*2O IS USED, FOG NOZZ ARE PREF. H*2O
MAY BE USED TO COOL CLSD CNTNRS (SUPDAT)
Unusual Fire/Explosion Hazard:KEEP CNTNRS TIGHTLY CLSD. ISOLATE FROM
HEAT, ELEC EQUIP, SPKS & OPEN FLAME. CLSD CNTNRS MAY EXPLODE WHEN
EXPOSED TO EXTREME HEAT. APPLICTN TO HOT SURFS (SUPDAT)

Accidental Release

Spill Release Procedures:REMOVE ALL SOURCES OF IGNITION. VENTILATE &
REMOVE W/INERT ABSORBENT.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:USE ONLY W/ADEQ VENT. AVOID BRTHG VAP
& SPRAY MIST. AVOID CONT W/SKIN & EYES. CONTENTS ARE EXTREMELY
FLAMM. KEEP AWAY FROM HEAT, SPKS & OPEN FLAME.
Other Precautions:VAPS WILL ACCUM READILY & MAY IGNITE EXPLOSIVELY.
DURING USE & UNTIL ALL VAPS ARE GONE:KEEP AREA VENTED; DO NOT
SMOKE; EXTING ALL FLAMES, PILOT LIGHTS & HEATERS; TURN OFF STOVES,
ELEC TOOLS & APPLIANC ES & ANY OTHER SOURCES OF IGNIT.(SUPDAT)

Exposure Controls

Respiratory Protection:IF PERSONAL EXPOSURE CANNOT BE CONTROLLED BELOW
APPLICABLE LIMITS BY VENTILATION, WEAR NIOSH/MSHA APPROVED
RESPIRATORY DEVICE FOR PROTECTION AGAINST MATERIALS IN INGREDIENTS
SECTION.
Ventilation:LOC EXHST PREF. GEN EXHST ACCEPT IF EXPOS TO MATLS IN INGS
IS MAINT BELOW APPLIC EXPOS LIMS. REFER TO OSHA STDS (ING 4)
Protective Gloves:IMPERVIOUS GLOVES .
Eye Protection:CHEMICAL WORKERS GOGGLES .
Other Protective Equipment:NONE SPECIFIED BY MANUFACTURER..
Work Hygienic Practices:WASH HANDS AFTER USING.
Supplemental Safety and Health
FIRE FIGHT PROC:TO PVNT PRESS BUILD-UP & POSS AUTOIGNIT/EXPLO WHEN
EXPOSED TO EXTREME HEAT. EXPLO HAZ:REQS SPECIAL PRECS. DURING EMER
CNDTNS OVEREXP TO DECOMP PRODS MAY CAUSE HLTH HAZ. SYMPS MAY NOT B
E IMMED APPARENT. GET MD. OTHER PREC:CONSULT NFPA CODE. USE APPRVD
BONDING & GROUNDING PROCS. KEEP CNTNR CLSD (ING 2)

Chemical Properties

Boiling Pt:B.P. Text:>132F,>56C
Vapor Pres:SEE ING
Vapor Density:HVR/AIR
Evaporation Rate & Reference:SLOWER THAN ETHER
Appearance and Odor:NONE SPECIFIED BY MANUFACTURER.
Percent Volatiles by Volume:100

Stability

Stability Indicator/Materials to Avoid:YES
NONE SPECIFIED BY MANUFACTURER.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:BY FIRE:CO*2, CO.

Disposal

Waste Disposal Methods:WASTE FROM PROD MAY BE HAZ AS DEFINED UNDER RCRA
40CFR261. WASTE MUST BE TESTED FOR IGNITABILITY TO DETERM APPLIC
EPA HAZ WASTE NUMBERS. INCIN IN APPRVD FACILITY. DO NOT INCIN CLSD
CNTNR. DISP OF I/A/ W FED, STATE & LOC REGS REGARDING POLLUTION.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.